The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Oscillometric devices are widely used for automatic cuff blood pressure (BP) measurement. These devices estimate BP from the oscillometric cuff pressure waveform using population average methods. Hence, the devices may only be accurate over a limited BP range. The objective was to evaluate a new patient-specific method, which estimates BP by fitting a physiologic model to the same waveform. One-hundred...
Most existing non-contact monitoring systems are limited to detecting physiological signs from a single subject at a time. Still, another challenge facing these systems is that they are prone to noise artifacts resulting from motion of subjects, facial expressions, talking, skin tone, and illumination variations. This paper proposes an efficient non-contact system based on a digital camera to track...
The objective of this paper was to investigate texture feature variability in ultrasound video of the carotid artery during the cardiac cycle in an attempt to define new discriminatory biomarkers of the vulnerable plaque. More specifically, in this paper, 120 longitudinal ultrasound videos, acquired from 40 normal (N) subjects from the common carotid artery and 40 asymptomatic (A) and 40 symptomatic...
Many clinical assessment protocols of the lower limb rely on the evaluation of functional movement tests such as the single leg squat (SLS), which are often assessed visually. Visual assessment is subjective and depends on the experience of the clinician. In this paper, an inertial measurement unit (IMU)-based method for automated assessment of squat quality is proposed to provide clinicians with...
The inspired sinewave technique is a noninvasive method to measure airway dead space, functional residual capacity, pulmonary blood flow, and lung inhomogeneity simultaneously. The purpose of this paper was to assess the repeatability and accuracy of the current device prototype in measuring functional residual capacity, and also participant comfort when using such a device. To assess within-session...
In this paper, thorough improvement of pulse monitoring and analysis equipment with a headset structure is presented. In order to study the most suitable infrared wavelength for the acquisition of the pulse wave at the earlobe, Monte Carlo simulation was adapted. Both high frequency noise and baseline drift, generated in the signal acquisition process, are considered. To further optimize the system...
As the burden of non-communicable diseases such as cancer continues to rise in low- and middle-income countries (LMICs), it is essential to identify and invest in promising solutions for cancer control and treatment. Point-of-care technologies (POCTs) have played critical roles in curbing infectious disease epidemics in both high- and low-income settings, and their successes can serve as a model for...
The last few years has seen a proliferation of wearable electrocardiogram (ECG) devices in the market with applications in fitness tracking, patient monitoring, athletic performance assessment, stress and fatigue detection, and biometrics, to name a few. The majority of these applications rely on the computation of the heart rate (HR) and the so-called heart rate variability (HRV) index via time-,...
The design and fabrication of a wound healing device for chronic wounds, with multiple functions for controlled drug delivery and exudate removal, has been described in this paper. The structural features have been machined and modified through laser cutting in a biocompatible polymer cast. Miniaturized versions of electronically actuated (lead-screw and pulley) mechanisms are used for the specific...
Real-time evaluation of novel prosthetic control schemes is critical for translational research on artificial limbs. Recently, two computer-based, real-time evaluation tools, the target achievement control (TAC) test and the Fitts’ law test (FLT), have been proposed to assess real-time controllability. Whereas TAC tests provides an anthropomorphic visual representation of the limb at the cost of confusing...
The inspection of live excised tissue specimens to ascertain malignancy is a challenging task in dermatopathology and generally in histopathology. We introduce a portable desktop prototype device that provides highly accurate neural network classification of malignant and benign tissue. The handheld device collects 47 impedance data samples from 1 Hz to 32 MHz via tetrapolar blackened platinum electrodes...
Qualitative assessments of the blink reflex are used clinically to assess neurological status in critical care, operating room, and rehabilitative settings. Despite decades of literature supporting the use of quantitative measurements of the blink reflex in the evaluation of multiple neurological disorders, clinical adoption has failed. Thus, there remains an unmet clinical need for an objective,...
The design of effective transcutaneous systems demands the consideration of inevitable variations in tissue characteristics, which vary across body areas, among individuals, and over time. The purpose of this paper was to design and evaluate several printed antenna topologies for ultrahigh frequency (UHF) transcutaneous power transfer to implantable medical devices, and to investigate the effects...
This paper proposes a new approach to automatically detect dementia. Even though some works have detected dementia from speech and language attributes, most have applied detection using picture descriptions, narratives, and cognitive tasks. In this paper, we propose a new computer avatar with spoken dialog functionalities that produces spoken queries based on the mini-mental state examination, the...
The objective of this paper is development of an inexpensive point-of-care sensor for detecting the primary heart failure marker peptide, NT-proBNP. The device technology is based on an antibody sandwich assay, but with three innovative aspects. First, chemical amplification is carried out via oxidation of silver nanoparticles (NPs) attached to signaling antibodies rather than by enzymatic amplification...
Batches of pharmaceuticals are sometimes recalled from the market when a safety issue or a defect is detected in specific production runs of a drug. Such problems are usually detected when patients or healthcare providers report abnormalities to medical authorities. Here, we test the hypothesis that defective production lots can be detected earlier by monitoring queries to Internet search engines...
The problem of creating a personalized seizure detection algorithm for newborns is tackled in this paper. A probabilistic framework for semi-supervised adaptation of a generic patient-independent neonatal seizure detector is proposed. A system that is based on a combination of patient-adaptive (generative) and patient-independent (discriminative) classifiers is designed and evaluated on a large database...
Varicose vein surgeries are routine outpatient procedures, which are often performed under local anaesthesia. The use of local anaesthesia both minimises the risk to patients and is cost effective, however, a number of patients still experience pain during surgery. Surgical teams must therefore decide to administer either a general or local anaesthetic based on their subjective qualitative assessment...
One important index to assess left ventricular diastolic function is the quantitative measurement of atrioventricular junction (AVJ) motion in one cardiac cycle including systole and diastole. The best way to perform the measurement is to use a software tool that can conduct AVJ motion tracking from cine cardiovascular magnetic resonance (CMR) images. In this paper, a software tool for this purpose...
To more accurately trigger cardiac computed tomography angiography (CTA) than electrocardiography (ECG) alone, a sub-system is proposed as an intermediate step toward fusing ECG with seismocardiography (SCG). Accurate prediction of quiescent phases is crucial to prospectively gating CTA, which is susceptible to cardiac motion and, thus, can affect the diagnostic quality of images. The key innovation...